I posted in another thread asking if there might be a way to create a custom <MyVariable>, with the same scope and functionality of <xypath>/<xyicons>/<xydata>/etc.
My particular use case was described in my post, but essentially I'd like to turn a repetitive string that I use throughout XY (CFA/Scripts/Toolbar/etc) into its own variable.
A simple .ini file in the XY folder could suffice, a more advanced option might be a .xys script that is run at XY start-up to allow the user to generate more complex variables. These variables could then be used across XY in the GUI and scripts, just like <xypath>/<xydata>/etc.
Defining Global Variables on Start-up
-
WirlyWirly
- Posts: 312
- Joined: 21 Oct 2020 23:33
- Location: XY 64-Bit | Win 10 @ 100% (3440x1440)
-
eil
- Posts: 1864
- Joined: 13 Jan 2011 19:44
Re: Defining Global Variables on Start-up
I'd propose you to investigate aliases, may help in your variable desire. Plus, there is a way to run script on start, you'll just need to run XY through .lnk with parameters.
Win 7 SP1 x64 100% 1366x768|1900x1080
-
highend
- Posts: 14925
- Joined: 06 Feb 2011 00:33
- Location: Win Server 2022 @100%
Re: Defining Global Variables on Start-up
Aliases work in CFAs?
Another way would be an environment variable for the current user. The only current problem: XY only reads some standard environment variables, not all defined. Maybe a feature wish to change that?
Another way would be an environment variable for the current user. The only current problem: XY only reads some standard environment variables, not all defined. Maybe a feature wish to change that?
One of my scripts helped you out? Please donate via Paypal
-
eil
- Posts: 1864
- Joined: 13 Jan 2011 19:44
Re: Defining Global Variables on Start-up
Don't know, just remembered smth along the lines. If they don't, This could be good idea for new feature - alias support everywhere.(and that would be quite a "user defined variable")
Win 7 SP1 x64 100% 1366x768|1900x1080
-
highend
- Posts: 14925
- Joined: 06 Feb 2011 00:33
- Location: Win Server 2022 @100%
Re: Defining Global Variables on Start-up
The problem is: Alias definitions begin with
How should XY definitely know if something inside a string is an alias or a simple folder name part?
Alias:
CFA:
@How should XY definitely know if something inside a string is an alias or a simple folder name part?
Alias:
@scripts=<xydata>CFA:
txt>::load "R:\tmp\@scripts\notme.xys";One of my scripts helped you out? Please donate via Paypal
-
eil
- Posts: 1864
- Joined: 13 Jan 2011 19:44
Re: Defining Global Variables on Start-up
IMO, i'd just make @name be treated like $name(how it kinda is now, but not everywhere), and @-at_start not interpreted any other way.